Flowline EchoBeam LR83 80 GHz Radar Level Transmitter
Flowline EchoBeam LR83 80 GHz Radar Level Transmitter
The Flowline EchoBeam® LR83 is a conduit-terminated, display-equipped member of the 80 GHz radar family. It is rated to 30 m (98.4 ft) on liquids and 15 m (49.2 ft) on solids. Accuracy is ±2 mm, with a tight 6° beam. It is offered general purpose or intrinsically safe (cCSAus, ATEX, IECEx). Output is either 4-20 mA plus HART 7 or Modbus RS485. The process temperature rating is 100 °C. The NEMA 4X (IP66/67) enclosure has a clear polycarbonate cap over the LCD. The PVDF antenna and zero dead band are shared with the rest of the family.
The LR80 relies on the app alone, but the LR83 can be configured four ways. The options are the LevelTap app over Bluetooth, the push-button LCD, HART or Modbus. Low 9 V (Modbus) or 12 V (loop) operation suits battery-powered remote sites. That is why Jadler pairs it with remote-monitoring packages for frac-water, mining and remote treatment sites across Western Canada. The intrinsically safe version is available for liquid applications with the 4-20 mA HART output. It requires Flowline’s LB12-1001 barrier.
- Features & Benefits
- Applications
- Product manuals
- Product specs
- 80 GHz radar for reliable, maintenance-free operation
- 30 m liquid / 15 m solids range with ±2 mm accuracy and a 6° beam
- LCD push-button display for level or flow indication and adjustment
- Four ways to configure — LevelTap app, LCD, HART or Modbus
- General purpose or intrinsically safe — cCSAus, ATEX, IECEx
- IP66/67 PBT-FR enclosure for outdoor installations in all weather
- Zero dead band and optional measurement through plastic or fibreglass tank walls
- Low 9 V or 12 V operation for battery-powered systems
- Bulk storage, process tanks and waste sumps
- Open channels, weirs, canals and reservoirs
- Clarifiers and neutralization tanks in water and wastewater
- Medium silos, bins, conveyors and stockpiles (solids)
- Battery-powered remote monitoring sites
| Maximum range | Liquid: 98.4 ft (30 m), dielectric ≥ 10, no agitation; Solids: 49.2 ft (15 m), dielectric ≥ 6, no dust |
|---|---|
| Frequency / beam angle | 80 GHz, W-band, FMCW / 6° |
| Accuracy | 0.4–30 m: ±2 mm; 0–0.39 m: ±10 mm |
| Dead band / min. dielectric | 0 mm / ≥ 1.6 |
| Signal output | 4-20 mA two-wire with HART 7 (max. 1,000 ft), or Modbus RS485 9600 baud (max. 3,937 ft) |
| Supply | 12–30 V DC (loop) or 9–27 V DC (Modbus); max. 22.5 mA / 1.5 W |
| Display / configuration | LCD dot matrix; LevelTap app (Bluetooth 5.0) or push button |
| Process temperature / pressure | −40 to 100 °C (−40 to 212 °F); −14.5 to 43.5 psi (−1 to 3 bar) |
| Enclosure | NEMA 4X (IP66/67); PBT-FR body, clear polycarbonate cap, PVDF antenna |
| Connections | 1/2″ NPT or M20 conduit; 1 1/2″ NPT or 1 1/2″ G process mount |
| Classification | General purpose: cCSAus, UL 61010-1 and C22.2 No. 61010-1-12; Intrinsically safe: cCSAus, ATEX, IECEx, Class I Div 1 Groups A–D, Ex ia IIC T6…T5 Ga |
| Compliance | FCC, ISED, CE/RED, UKCA, RoHS, REACH, CRN |