ISOIL ISOMAG MV110 / MV145 / MV210 Flow Transmitters
ISOIL ISOMAG MV110 / MV145 / MV210 Flow Transmitters
ISOIL ISOMAG flow transmitters (converters) turn any ISOMAG sensor — MS2500, MS1000, MS600 and the insertion elements — into a complete electromagnetic flow meter. All three mount integrally on the sensor or remotely, measure bidirectionally, offer empty-pipe detection, low-flow cut-off and built-in meter verification, and are programmed from the front keypad or a PC over mini-USB.
MV110 is the versatile mains- or DC-powered standard for clean water and general service (±0.4%). MV145 is the battery-powered specialist (±0.4%, ±0.25% on request) for metering points with no mains supply, with a 15-year-plus battery life estimate and MID MI-001 approval with the MS2500. MV210 is the high-performance model (±0.2% of reading) with batching, BACnet and M-Bus for demanding process, sludge and slurry duty. Jadler Industries assembles, programs and configures every unit before shipment.
- Features & Benefits
- Applications
- Product manuals
- Product specs
- MV110 — versatile control: ±0.4% accuracy; 100–240 VAC, 24–36 VAC/VDC or 12–48 VDC; 4–20 mA, pulse, HART, Modbus RTU, M-Bus
- MV145 — battery powered: ±0.4% (±0.25% optional); lithium or alkaline packs, 15+ year estimated life; 4–20 mA + Modbus RTU; 4 GB logger
- MV210 — high performance: ±0.2% of reading from 0.5 m/s; batch controller; Modbus, HART, BACnet, M-Bus; OIML R49
- Integral or remote mounting on all ISOMAG sensors (approx. 15 m remote for MV145, 40 m for MV110 / MV210 without amplifier)
- Bidirectional measurement, empty-pipe detection, low-flow cut-off
- Built-in verifier (BIV) — integrated meter verification and condition monitoring
- Backlit 128×64 graphic display with 3-key programming; PC set-up via mini-USB
- CEC certified for general-purpose (GP) rated areas through Intertek special inspections
- Nylon, aluminum or SS304 enclosures; IP67 (IP68 on request); field-proven in Canadian winters
- Jadler configuration service — calibration data, outputs and parameters programmed before shipment
- Potable water and water networks (MV110 / MV145)
- Remote, unpowered metering points and billing (MV145)
- Wastewater, sludge and slurries (MV210)
- Viscous and solids-laden fluids such as cream and polymer (MV210)
- Batching and dosing (MV210)
- HVAC and energy metering
| Models | MV110 (versatile control) · MV145 (battery powered) · MV210 (high performance) |
|---|---|
| Accuracy | MV110: ±0.4% (±0.8% std / ±0.4% optional per ISOIL) · MV145: ±0.4%, ±0.25% on request · MV210: ±0.2% of reading from 0.5 m/s |
| Repeatability | MV110: ±0.2% · MV145: better than ±0.2% · MV210: ±0.1% |
| Mounting | Integral (compact) or remote (separate) on MS1000, MS2500, MS600, MS501 inline and MS3780 / MS3820 insertion sensors |
| Power supply | MV110 / MV210: 100–240 VAC, 24–36 VAC/VDC or 12–48 VDC, optional rechargeable backup battery · MV145: lithium or alkaline batteries (15+ year estimate) or mains / solar DC |
| Analog I/O | MV110 / MV210: 1–2 × 4–20 mA outputs (HART optional on output 1) · MV145: 1 × 4–20 mA output, up to 2 pressure / temperature inputs |
| Digital I/O | MV110 / MV210: 1–2 digital outputs (1,250 Hz), 1 digital input · MV145: 2–4 digital outputs, 1–3 digital inputs |
| Communication | MV110: Modbus RTU (RS485), HART, M-Bus · MV145: Modbus RTU (RS485) · MV210: Modbus RTU, HART, M-Bus, BACnet |
| Data logging | MicroSD 4–32 GB (optional on MV110 / MV210; 4 GB standard on MV145) |
| Display | Backlit 128×64 pixel graphic display, 3 programming keys (MV145: mains-powered version) |
| Enclosure | Nylon with 15% glass fibre, painted die-cast aluminum, or AISI 304 stainless steel |
| Ambient temperature | Nylon −10 to +50 °C; aluminum / SS304 −20 to +60 °C (LCD pauses below −20 °C, resumes above) |
| Protection rating | IP67 standard; IP68 on request (aluminum) |
| Minimum fluid conductivity | ≥ 5 µS/cm |
| Special functions | Bidirectional, empty-pipe detection, low-flow cut-off, alarm limits, built-in verifier (BIV); MV210 adds batch control |
| Approvals | Canadian Electrical Code (CEC) certified for use in GP rated areas through Intertek special inspections; CE; MV110 / MV145 with MS2500: MID MI-001 (MV110 also MI-004); MV210: OIML R49 |