ISOIL ISOMAG MS2500 Flanged Electromagnetic Flow Meter
ISOIL ISOMAG MS2500 Flanged Electromagnetic Flow Meter
The ISOIL ISOMAG MS2500 is a full-bore flanged electromagnetic flow sensor and the widest-ranging model in the ISOMAG line, covering 1″ to 120″ (DN 25–DN 2000) with ANSI Class 150 and Class 300 B16.5 flanges as standard and higher pressure classes on request. With no moving parts and no obstruction to the pipe, it measures bidirectionally with a flat calibration curve and long-term stability in potable water, wastewater, sludge, slurry and chemical service.
Liner options (polypropylene, Rilsan, ebonite, PTFE, PFA, Abral) and five electrode materials cover most temperature and compatibility requirements, and the fully potted, IP68 / NEMA 6P sensor can be supplied with a stainless-steel body for direct-burial or high-saline sites. Pair it with an ISOMAG MV110, MV145 or MV210 transmitter (integral or remote) for integrated meter verification, and let Jadler Industries handle model selection, sizing reports and configuration.
- Features & Benefits
- Applications
- Product manuals
- Product specs
- 1″ to 120″ line sizes (DN 25–DN 2000) — one platform from small process lines to large mains
- Full-bore, no moving parts — no pressure drop, bidirectional measurement
- System accuracy to ±0.2% of reading with the MV210 transmitter (±0.4% with MV110 / MV145)
- ANSI Class 150 and 300 flanges, CRN-registered; higher classes on request
- Six liner materials — polypropylene, Rilsan, ebonite, PTFE, PFA, Abral — for temperatures from −20 °C to 180 °C
- Five electrode materials — stainless steel, Hastelloy C-276, tantalum, titanium, platinum
- IP68 / NEMA 6P fully potted sensor; stainless-steel body option for direct burial
- Drinking-water approvals — WRAS, NSF, DM174 material certifications
- Integral or remote transmitter with built-in meter verification (BIV)
- Potable water
- Wastewater and wastewater sludge
- Coagulants, flocculants and polymer
- Mining slurries
- Produced water
- Conductive fluids ≥ 5 µS/cm
- HVAC and district energy
| Line sizes | 1″ to 120″ (DN 25 to DN 2000) |
|---|---|
| Process connection | ANSI B16.5 flanged, Class 150 / 300 standard (CRN-registered); UNI, DIN, JIS and higher pressure classes on request |
| Accuracy (system) | Transmitter dependent: ±0.4% of reading with MV110 / MV145; ±0.2% with MV210 (velocity ≥ 0.5 m/s) |
| Repeatability | ±0.1% |
| Flow range (linear accuracy) | 0.5 to 10 m/s (1.64 to 32.8 ft/s); e.g. 2″: 15–317 GPM, 12″: 555–11,095 GPM |
| Minimum fluid conductivity | ≥ 5 µS/cm (MV110 / MV145 / MV210) |
| Liner materials | Polypropylene, Rilsan, ebonite, PTFE, PFA, Abral (natural rubber) |
| Liner temperature limits | PP 0–60 °C; Rilsan 0–70 °C; ebonite −5–80 °C; PTFE −20–130 °C; PFA −20–180 °C; Abral −20–70 °C |
| Electrode materials | Stainless steel AISI 316L, Hastelloy C-276, tantalum, titanium, platinum |
| Body / flange material | Carbon steel (painted) standard; AISI 304 / 316 stainless steel optional |
| Protection rating | IP68 / NEMA 6P (fully potted); IP67 compact version |
| Material certifications | WRAS, NSF, DM174 |
| Custody transfer | MID MI-001 / MI-004 certified sizes when paired with MV110 / MV145 |
| Face-to-face (Class 150) | 2″: 200 mm · 4″: 250 mm · 6″: 300 mm · 8″: 350 mm · 12″: 500 mm |